banner

The work process and function description of Yaoertai YET845 rolling door wireless motor controller

341 Published by xia, Crystal Feb 28,2019

Want create site? Find Free WordPress Themes and plugins.

The?Yaoertai YET845 rolling door wireless motor controller is mainly to complete the switch control of the moving door, and has flexible settings and practical protection functions. The following is the working process and function description of the?Yaoertai YET845 rolling door wireless motor controller product:

Rolling door wireless motor controller.

Before Work:

1, The remote control pairing

Press the LEARN button on the control panel. When the red LED is turned off, the LEARN button is released. At this time, the controller related information is deleted and restored to the factory setting (maximum running stroke 60S, automatic door closing delay time 30S); Press the LEARN button again, the red LED will light up, and at the same time release the LEARN button, the LED will go out. At this time, the controller is in the remote control learning state, press any button of the remote controller that needs to be learned (recommended not to use the D button, in case the system has an error in the single button mode). The LED on the controller flashes 5 times to indicate successful learning.

2, The maximum operating stroke setting of the moving door

After the remote control is paired, you can control the door down through the B button of the remote control (ie, the down button), go to the down limit to completely close the door, then press the TIME button, the red LED is always on, release the TIME button, and the LED remains. Always on, at this time, press the A button of the remote control (ie, open the door), the system opens the door control link, the red LED and FLASH relays begin to flash at a frequency of 600ms on / 600ms off, and the controller keeps this state until the door is fully open. The upstream stop, and then press the B button (ie, the door close button) within the time that the motor can withstand, the system exits the current state, keeps the door fully open, and ends the maximum running stroke setting.

3, Moving door automatic closing delay time setting

Press the TIME button, the red LED is always on, let go of the TIME button, the LED stays on. At this time, press the D button of the remote control, the red LED and the FLASH relay start to flash at the frequency of 250ms/250ms, and the system keeps this state. Until the D button is pressed again, the system exits the current state and ends the setting of the automatic door closing delay time.

4, System mode settings

You can selectively use the AC (automatic closing), L/R (switching link switching), and 1 KEY/4 KEY mode to switch between the three functions depending on the environment.

Their functions are: AC, enable this function, when the door is running to the top, the controller will automatically delay the set time, and the door closing action will be executed after the delay is completed;

L/R, using this function, the uplink and downlink outputs are switched;

1/4KEY, with this function, the controller can only be controlled using the buttons we have previously learned.

At Work:

After the system is powered on, it is in the uplink stop state, waiting for all valid signals and acting. The following details:

4 KEY Mode:

The uplink and downlink outputs can be set using the L/R hopping cap. The uplink and downlink described below are in normal mode and are not switched.

Upward Action:

When the door is not fully open or not in the up action mode, you can press the A button of the remote control (ie, the up button) to control the system to open the action. During the uplink process, you can control the stop and reverse the down action. The maximum run time is reset each time the run action is updated. If the running action is not modified, the system stops up until the upper limit is reached or the maximum running time ends. At this time, if the AC function is enabled, the system starts timing the automatic door closing delay. If an obstacle is encountered or received during the timing. The C button of the remote control (ie the stop button) has been learned, the time is cleared, and the time is re-timed. After the timing is completed, the downlink action is started.

Downward Action:

When the door is not fully closed or not in the down mode, you can press the B button of the remote control (ie, the down button) to control the system’s downlink action. During the downlink process, you can control the stop and reverse the upstream action. The maximum run time is reset each time the run action is updated. If an obstacle is encountered during the downlink process, the system will delay the uplink action by delaying 0.5S.

1 KEY Mode:

The uplink and downlink outputs can be set using the L/R hopping cap. The uplink and downlink described below are in normal mode and are not switched.

Action Process:

In the 1 KEY mode, the system operation uses the key value of the learned remote controller to control the actions of uplink, stop, down link, stop, etc., ascending-stop-down-stop-up-up loop action, and the other is the same as the 4 KEY mode.

rolling door wireless door application,

YET845 rolling door wireless motor controller features

1. On/Off Control Link Switchable.

The system’s on/off terminals can be defined according to their own situation;

2. Superior Load Capacity.

Each channel of the system can be connected to 250VAC/10A load, safe and stable control;

3. Flexible System Settings.

The system can set automatic door closing, switch link switching, 1key/4key mode as needed;

4. Travel Memory To Ensure Accurate Door Switch.

The system has the function of travel time memory, which can make the motor run at unnecessary time and save energy;

5. Anti-Pinch Protection.

When the moving door is in the automatic door closing delay or when the door is being closed, if there is an obstacle, the controller will not close the door to prevent pinching the obstacle;

6. Motor Over-Operation Protection To Prevent Motor Burnout

Set the maximum running time to prevent the moving door from running out of time to avoid burning the motor;

7. Very Little Standby Current:

Adopt advanced power-saving technology, working current mA level.

Did you find apk for android? You can find new Free Android Games and apps.

2019 China Shenzhen Public Security Expo!

Focus on security technology innovation and lead the development of AI industry. The 17th China I...

Do you like ? 270

Read more

Celebrate the 14th anniversary of Yaoertai !

On May 11, 2019, our company Yaoertai was founded 14th anniversary! In the past 14 years, we hav...

Do you like ? 470

Read more

2019, let’s go hiking together!

Saturday, the first week of work in 2019, On a sunny afternoon, Yaoertai, all business colleagues...

Do you like ? 1,033

Read more

The 28th Beijing Construction Expo will be held soon, and invite you to participate in the grand event!

The 28th China (Beijing) International Building Decoration and Materials Expo will be held on Mar...

Do you like ? 1,041

Read more

R+T Asia Shanghai Door and Window Sunshade Exhibition, the opening of the 2019 is coming soon

The 15th R + T Asia Shanghai Door and Window Sunshade Exhibition will be held from February 27th ...

Do you like ? 980

Read more

Difference between 433 remote control and 315 remote control and its code method

The frequency used by the radio remote control is 433Mhz or 315Mhz, also referred to as 433 remot...

Do you like ? 3,245

Read more

Infrared alarm principle, function and installation method

The infrared alarm can detect the infrared rays emitted by the human body, and is composed of an ...

Do you like ? 899

Read more

Congratulation YET Global Sources Electronics Exhibition bring to a successful close

Congratulation YET Global Sources Electronics Exhibition bring to a successful close Gate remote ...

Do you like ? 1,002

Read more
YET2018All Rights ReseverdTechnical Support:Baiila